logo

FM200 Gas System Cylinder Without Pollution For Battery Room

1 Takım
MOQ
Anlaşılabilir
fiyat
FM200 Gas System Cylinder Without Pollution For Battery Room
Özellikleri Fotoğraf Galerisi Ürün Açıklaması Fiyat talebi
Özellikleri
Teknik Özellikler
Model NO.: QMP32/2.5, QMP40/4.2, QMP52/2.5, QMP70/4.2, QMP100/4.2, QMP147/2.5, QMP150/4.2, QMP180/2.5, qmp180/2
Cilt (L): 32,40,52 , 70, 100,106,120, 147,150, 180
Depolama Basıncı: 4.2mpa; 2.5mpa
İç çap: 300, 350, 400
Renk: Kırmızı
Vurgulamak:

FM200 gas cylinder for battery room

,

pollution-free FM200 cylinder

,

FM200 fire suppression cylinder

Temel bilgiler
Menşe yeri: Çin
Marka adı: Air Giant
Sertifika: CAL,CMA,CNAS,ILAC-MRA,CCC
Model numarası: QMP32/2.5, QMP40/4.2, QMP52/2.5, QMP70/4.2, QMP100/4.2, QMP147/2.5, QMP150/4.2, QMP180/2.5, qmp180/2
Ödeme & teslimat koşulları
Ambalaj bilgileri: Kabarcık çanta veya kağıt ile kontrplak dış kutu
Teslim süresi: 10-15 iş günü
Ödeme koşulları: L/C,D/P,T/T,Western Union,Paypal,Kredi kartı
Yetenek temini: Haftada 28000 takım
Ürün Açıklaması

FM200 Gas System Cylinder Without Pollution For Battery Room


Description


The table shows the specific parameters of several conventional bottles of different sizes

NO.

Specifications

4.2MPa system

1

Capacity

40Ltr,70Ltr,100Ltr,120Ltr,150Ltr,180Ltr

2

Device model

QMP40/4.2, QMP70/4.2, QMP100/4.2, QMP120/4.2, QMP150/4.2, QMP180/4.2

3

Storage pressure

4.2MPa

4

Max. working pressure

5.3 MPa (50℃)

5

Min. working pressure

3.6MPa (0℃)

6

 Filling rate

FM200≤1.0 kg/L / Novec1230≤1.42kg/L

7

Discharge time

≤10s

8

Power

DC24V/1.5A

9

Nitrogen driving device

6.0±1.0MPa

10

Storage surroundings

Temperature:0~50°C

Relative humidity:<97%

11

Proportion

≤800m2

12

Volume

≤3600m3


Components


The bottle part is composed of steel cylinder and cylinder valve

                   

FM200 Gas System Cylinder Without Pollution For Battery Room 0   FM200 Gas System Cylinder Without Pollution For Battery Room 1    FM200 Gas System Cylinder Without Pollution For Battery Room 2


Application


The pipe network type fm200 fire suppression system is suitable for a lot of places and several kinds of fires. The followings are some examples for customer as reference:

 

- Telecommunications and data processing

- Switch gear rooms

- Military applications and cell sites

- High-tech medical application

- Computer rooms

- Telecommunication centers

- Records and data archives

- Testing/imaging equipment

- Reference material

- Chemical laboratories


FM200 Gas System Cylinder Without Pollution For Battery Room 3


Package


We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.


FM200 Gas System Cylinder Without Pollution For Battery Room 4

Önerilen Ürünler
Bizimle temasa geçin
İlgili kişi : Mr. Missaya Lu
Tel : +86 188 1945 1181
Kalan karakter(20/3000)